For Sale COBAS INTEGRA 800 Chemistry Analyzer

For Sale COBAS INTEGRA 800 Chemistry Analyzer

Location:Przeźmierowo, Poland

Available quantity:1

orCall +48 601 333 666

Description

COBAS INTEGRA 800 - USED, WORKING CONDITION Specifications System Random and continuous access, sample selective analyser Integration of 4 measuring principles 72 tests onboard Absorbance Photometry: Enzymes and Substrates Turbidimetry: Specific Proteins, Drugs of Abuse Fluorescence Polarimetry: Therapeutic Drugs, Thyroid Tests Ion-Selective Electrode Potentiometry: Na+ ,K+ ,Cl– and Li+ Test Throughput Up to 855 tests/hr (including electrolytes) Sample Types Serum, Plasma, Urine, CSF, Hemolysate and Whole Blood Sample Handling Rack system for samples, calibrators and controls: RD5 rack, RD15 rack, RD12+3 rack, Multi Rack; Roche standard rack and tray compatibility; In- and Out-Tray for 75 samples each; Automatic predilution; User definable postaction 1 & 2: dilute or concentrate; Temperature controlled: calibrators and controls, 20°C (68°F) Samples below 32°C (90°F); Barcode reading via LED scanner, with immediate STAT recognition Sample Container Types Primary tubes: 5 to 10ml; 16x100, 16x75, 13x100, 13x75mm with closed cap for systems with closed tube sampling option for HbA1c. (please contact Roche for list of compatible suppliers); Hitachi microcup, 500µl; Hitachi standard cup, 1.5ml; COBAS cup, 650µl; Eppendorf cup, 1.5ml; Cup on tube definable Sample Volume Typically 2 to 10µl per test, ISE indirect 20µl, ISE direct 97µl Sample Barcode Types Code 128, Codabar, Code 2 of 5 interleaved, Code 39 Reagents Onboard 68 cobas c packs, 50-800 tests per cobas c pack capacity Reagent compartment cooled to 8°C Onboard stability up to 6 months, calibration typically each lot User Defined Reagents up to 5 Development Channels are available on request. Reaction Cells Holds 3000 disposable cuvettes with 5mm path length, and 120-240µl reaction volume Control Unit HP workstation with RISC processor running X Windows System Interfaces RS 232 serial interface, bi-directional host interface, secured digital (web based) TeleService connection to Roche for screen sharing and remote help Electrical Requirements 100-125/200-240 Volts AC, 50 or 60Hz, consumption 1700VA Physical Dimensions Width: 190cm (74.8in); Depth: 90cm (35in); Height: 120 cm (47.3in) Weight 512kg (1126lbs) Water Requirements 5-7 liters per hour in operating mode, Type 1 NCCLS Certification CE, UL, C-UL Items are sold as-is with no returns or refunds available unless explicitly stated.

Specifications

ManufacturerCOBAS
ModelINTEGRA 800
ConditionUsed
Stock Number2741105
In stockYes
TypeChemistry Analyzer